TOVASURV-9000' MULTI-PARAMETER PATIENT MONITOR

TOVASURV-9000' MULTI-PARAMETER PATIENT MONITOR

Fr1 950 (CHF)

Quantité disponible:1

Description

1. CE approved by FDA
2. Standard configuration:
3/5 lead ECG SpO2 NIBP Temp REEE PR network rechargeable Lithium battery
3. Optional configuration:
Double Temp Double IBP thermal printer 12 lead ECG AND CO2 (general public/side smoke) wall mount cart
SPECIFICATIONS
1. 12.1 polegada high-brightness TFT LCD screen, large digit display
2. Ergonomic design, portable, easy to use.
3. Simultaneous display of 7 ECG leads via one frame
4. Real-time ST segment and arrhythmia analysis
5. Date and waveform colors are adjustable
6. Unique digital SpO2 technology can work during precise movement and low perfusion
7. 96-hour charts and trend graphs and date storage
8. Compatible and Auto identify 3-lead and 5-lead ECG cable
9. Dual-wire NIBP pressure protection
10. Insulated floating, anti-defibrillation and anti-high-frequency interference protection
11. Dual-wire NIBP pressure protection
12. Networking with central monitoring system, up to 64 beds in one group
13. Multi-language: English, French, German, Italian, Portuguese, Spanish, Russian, Polish
Technical parameters
ECG
1. 5-lead or 3-lead selectable
2. Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
6. Protection: withstand 4000VAC/50Hz Voltage in insulation against electro and defibrillation
9. Alarm range: Adult: 15-300bpm
12. S-T detection: Yes, arrhythmia analysis: YES
NIBP
5. Measurement range: Adult: 10-270mmHg
SpO2
3. 0-69% not specified
Respiration
3. Alarm range: adult: 6-120 RPM
Temperature

Caractéristiques

ConditionNouvelle
Numéro de stock4724
2. standard configuration3/5 lead ECG SpO2 NIBP Temp REEE PR rechargeable network Lithium battery
3. optional configurationDouble Temp Double IBP 12-lead ECG AND CO2 thermal printer (general public/side smoke) wall bracket cart
3. delivery selectionI; II; III; AVR; AVL; AVF; VX; cal
4. gain selection12.5 mm/s, 25 mm/s, 50 mm/s
5. precision1bpm or 1% , whichever is greater
7. calibration signal1mv5%
8. operating modesdiagnosis, monitoring, surgery
10. pediatric/neonatal15-350bpm
11. alarm range-2.0mV-2.0mV
13. alarmYes, audible and visual alarm, revocable alarm events
1. methodImpedance RA-LL
2. operating modesmanual/automatic/STAT
3. unit of measurementmmHg/kPa selectable
4. measurement typessystolic, diastolic, average
6. overpressure protectionYes
7. resolution1 mmHg
8. precisionmean error and standard deviation per ANSI/AAMI sp-10 standard
9. alarmsystolic, diastolic, average
1. measuring range0-100%
2. precision2 digits (70 ~ 100% )
4. alarm range0-100%
2. pediatric/neonatal6-150 rpm
4. pediatric/neonatal6-150 rpm
5. apnea alarmYES
1. resolution0.1 degrees centigrade
2. channeldual-channel
3. alarm range0-50 degrees centigrade